WANLIN-303
Standalone photoelectric smoke alarm family
Review standalone, 433 MHz, LoRa or 4G candidates only after the exact hardware and radio version is identified.
Export product-family resource
Plan procurement with Standalone Smoke Alarms for Yunnan Wireless Fire Alarm: review model paths, specification inputs, evidence checks and questions to...
Direct answer
An export standalone smoke alarm detects smoke and provides a local audible warning without requiring a conventional fire alarm control panel. For fire safety projects, buyers should first define the protected space, required local alarm behaviour, reporting method, power arrangement and destination-market evidence.
This page is written for distributors, system integrators and project procurement teams. It is a product-family selection resource, not a claim that every variant has the same approval, radio module or market access.

Model reference image
The image identifies a WANLIN-307 family reference. Radio, power, label and evidence scope can differ by controlled configuration; confirm the SKU/BOM before using any formal product or compliance statement.
Open the WANLIN-307 product passport · Review the public evidence center
Verified manual data
Evidence scope: WANLIN-307 user manual, Ver 1.0. Documented manual configuration only; radio, platform, power and market variants require separate SKU/BOM confirmation.
| Detection principle | Infrared photoelectric smoke sensing with MCU processing |
|---|---|
| Rated working voltage | DC 3 V |
| Battery capacity | 2400 mAh |
| Standby current | ≤ 6 μA |
| Alarm current | ≤ 100 mA |
| Sound pressure | > 80 dB(A) at 3 m directly in front |
| Operating temperature | −10 °C to +50 °C |
| Relative humidity | ≤ 95% RH at 40 °C ± 2 °C |
| Alarm output | Audible and visual alarm |
| Low-voltage indication | Below 2.7 V; indicator and one chirp about every 40 s |
| Normal indicator | Indicator illuminates about every 40 s |
| Approximate weight | 140 g including battery |
| Manual-listed execution standard | GB 20517-2006 |
| Installation reference | GB 50116-2013; final layout must follow project design requirements |
Important: “GB 20517-2006” is presented here as the execution standard stated by this manual. This wording is not a third-party certificate claim and does not establish destination-market acceptance. The manual also advises against use where relative humidity exceeds 95%, air speed exceeds 5 m/s, or heavy dust, water mist, steam, oil mist or corrosive gas is present.
Site-specific planning lens
Ask for the current report or certificate scope, product photographs, rating-label artwork and manual revision so the reviewed product can be compared with the ordered product.
Existing site context: Wanlin Fire presents Yunnan Wireless Fire Alarm Systems with clear selection criteria, technical support, system compatibility details and global project supply options. Use that context to define the application; it does not replace model-specific technical or compliance review.
Remote notification does not replace the local audible warning. Define both functions and the party responsible for receiving and acting on remote events.
Distributors should confirm private-label scope, artwork ownership, manual languages, sample approval and how production changes will be communicated.
For this site's fire safety projects focus, the planning lens is “Yunnan Wireless Fire Alarm Systems.” Start with the decision that changes the architecture most: local alarm only, or local alarm plus remote event reporting.
Last reviewed: 2026-11-02 · Reviewed by Wanlin Fire Equipment for product-family and evidence-boundary consistency.
WANLIN-303
Review standalone, 433 MHz, LoRa or 4G candidates only after the exact hardware and radio version is identified.
WANLIN-307
Candidate configurations may include standalone, 433 MHz, LoRa, 4G or NB-IoT; availability and evidence must be confirmed per SKU/BOM.
WANLIN-309
Use when the project requires a local alarm plus a defined reporting path; verify gateway, network and destination-market requirements.
WANLIN-370
A smoke/heat/carbon-monoxide combination concept is not interchangeable with a smoke-only alarm; confirm the required sensing functions first.
Before purchase: request a model-specific evidence pack and have the destination-market requirements reviewed by a qualified local party.
Answers for buyers
A basic standalone alarm provides local detection and sound without a conventional panel. Connected variants may use a gateway, cloud platform or communication module, depending on the selected architecture.
Only if the selected hardware and product architecture support that path. Do not assume a radio module can be added to every local-only version; confirm the exact SKU/BOM and gateway requirements.
Communication modules, power arrangements, labels and other components may differ within a family. Evidence and purchasing documents should therefore identify the exact controlled configuration.
The project team should document local alarm behaviour, event buffering or retry expectations, supervision, user notification and the party responsible for restoring connectivity.
Select a combination concept only when the project explicitly requires its sensing functions. A smoke, heat and carbon-monoxide combination device is not automatically interchangeable with a smoke-only alarm.
Send the destination country, application, quantity, reporting method, preferred power arrangement and required delivery schedule to wanlinfirecontrol@163.com. Recommendations and formal claims remain subject to exact-model evidence review.
Browse product information · Read technical FAQs · Contact Wanlin Fire